Obiekt

Tytuł: Reliability and concurrent validity of the iHandy level mobile application to measure thoracolumbar range of motion in low back pain patients

Autor:

Ijaz, Nimra ; Riaz, Saima ; Raza, Tahreem ; Ali, Sidra

Abstrakt:

Introduction. The use of smartphone technology and software (apps), in addition to an inclinometer and goniometer, has ex-panded the clinician’s assessment possibilities. However, the legitimacy and trustworthiness of these cell phones and applications are still questioned. This study aimed to determine the reliability and concurrent validity of the iHandy level mobile application to measure the thoracolumbar range of motion in people with low back pain.Methods. This descriptive study included 40 participants, of which 20 were symptomatic, and 20 were asymptomatic for non-specific chronic pain in the lower back. Measurements were taken for extension, flexion, and left and right-side bending range of motion (ROM). Two investigators were involved. One measured ROM values with a Samsung iHandy level and inclinometer, and the second investigator registered the data. Two values were taken and the mean was used for further analysis. Measure-ments were taken at baseline and one-week follow-up.Results. In asymptomatic participants, the mobile application had ICC values of 0.81, 0.70, 0.79, and 0.85, while in symptomatic, regarding intra-rater reliability, these were 0.80, 0.78, 0.81Regarding the concurrent validity of mobile apps in asymptomatic patients, ICC values were 0.94, 0.93, 0.84, and 0.89, while in symptomatic patients, the ICC values were found to be 0.92, 0.89, 0.83, and 0.85 for flexion, extension, RLF, and LLF, respectively. These showed an excellent correlation between the inclinometer and mobile app regarding intra-rater reliability and concurrent validity.Conclusions. iHandy level smartphone applications might be considered reliable and valid for assessing thoracolumbar motion ranges in individuals with chronic pain in the lower back.

Wydawca:

Wydawnictwo Akademii Wychowania Fizycznego im. Polskich Olimpijczyków we Wrocławiu

Miejsce wydania:

Wrocław

Data wydania:

2024

Typ zasobu:

artykuł

Identyfikator zasobu:

oai:dbc.wroc.pl:131867

Język:

ang

Powiązania:

Physiotherapy Quarterly ; Physiotherapy Quarterly,2024,vol.32,nr4

Prawa:

Wszystkie prawa zastrzeżone (Copyright)

Prawa dostępu:

Dla wszystkich zgodnie z licencją

Licencja:

CC BY-NC-ND 4.0

Właściciel praw:

Wydawnictwo Akademii Wychowania Fizycznego im. Polskich Olimpijczyków we Wrocławiu

×

Cytowanie

Styl cytowania:

Ta strona wykorzystuje pliki 'cookies'. Więcej informacji