Obiekt

Obiekt planowany

Tytuł: Modeling and evaluation of performance of dual field-of-view common-aperture dual-band imaging system

Autor:

Wang, Qingsong ; Gao, Ming

Współtwórca:

Urbańczyk, Wacław. Redakcja

Opis:

Optica Applicata, Vol. 52, 2022, nr 4, s. 535-550 ; Optica Applicata is an international journal, published in a non-periodical form in the years 1971-1973 and quarterly since 1973. From the beginning of the year 2008, Optica Applicata is an Open Access journal available online via the Internet, with free access to the full text of articles serving the best interests of the scientific community. The journal is abstracted and indexed in: Chemical Abstracts, Compendex, Current Contents, Inspec, Referativnyj Zhurnal, SCI Expanded, Scopus, Ulrich’s Periodicals Directory ; kliknij tutaj, żeby przejść

Abstrakt:

For the modeling and evaluation of dual field-of-view (FOV) common-aperture dual-band imaging system performance, two factors must be considered at the same time. One is that the system must have a larger target acquisition range, and the other is that the detection range and recognition range of the system must be the same. In this paper, taking the dual FOV common-aperture visible/long-wave infrared (LWIR) imaging system as an example, the performance of the dual FOV common-aperture dual-band imaging system is modeled and evaluated using an imaging system performance model based on comprehensive resolution. Firstly, the target acquisition range of the dual FOV visible imaging system is analyzed, and the condition that the detection range is equal to the recognition range is obtained. Then, under the condition of common aperture, the target acquisition range and the relationship between detection range and recognition range of dual FOV LWIR imaging system are analyzed. The analysis results show that, under the condition of dual FOV and common aperture, when the detection and recognition ranges of the visible imaging system are equal, the detection and recognition ranges of the LWIR imaging system are not equal. When the detection and recognition ranges are close by reducing the comprehensive resolution, the target acquisition range of the dual FOV common-aperture dual-band imaging system will decrease.

Wydawca:

Oficyna Wydawnicza Politechniki Wrocławskiej

Miejsce wydania:

Wrocław

Data wydania:

2022

Typ zasobu:

artykuł

Identyfikator zasobu:

doi:10.37190/oa220405

Źródło:

<sygn. PWr A3481II> ; kliknij tutaj, żeby przejść ; kliknij tutaj, żeby przejść

Język:

eng

Powiązania:

Optica Applicata ; Optica Applicata, Vol. 52, 2022 ; Optica Applicata, Vol. 52, 2022, nr 4 ; Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki

Prawa:

Wszystkie prawa zastrzeżone (Copyright)

Prawa dostępu:

Dla wszystkich w zakresie dozwolonego użytku

Lokalizacja oryginału:

Politechnika Wrocławska

Tytuł publikacji grupowej:

Optica Applicata

Nazwa wydania Data
×

Cytowanie

Styl cytowania:

Ta strona wykorzystuje pliki 'cookies'. Więcej informacji