Object

Planned object

Title: Aspherical, sphero-cylindrical, toroidal, and ellipsoidal surfaces for designing astigmatic spectacle lenses with axis orientation

Creator:

Xiang, Huazhong ; Wang, Peng ; Zheng, Zexi ; Chen, Jiabi ; Wang, Cheng ; Zhang, Dawei ; Zhuang, Songlin

Contributor:

Urbańczyk, Wacław. Redakcja

Description:

Optica Applicata, Vol. 53, 2023, nr 3, s. 377-391 ; Optica Applicata is an international journal, published in a non-periodical form in the years 1971-1973 and quarterly since 1973. From the beginning of the year 2008, Optica Applicata is an Open Access journal available online via the Internet, with free access to the full text of articles serving the best interests of the scientific community. The journal is abstracted and indexed in: Chemical Abstracts, Compendex, Current Contents, Inspec, Referativnyj Zhurnal, SCI Expanded, Scopus, Ulrich’s Periodicals Directory ; click here to follow the link

Abstrakt:

In this paper, formulas for aspherical, sphero-cylindrical, toroidal, and ellipsoidal surfaces with astigmatic axes are derived. Based on this, four types of curved surfaces were designed to correct astigmatism with axis, and, subsequently, the lenses were simulated, fabricated, and measured. A total of ten spectacle lenses in two groups were designed. Those in the first group used identical optical parameters. The spherical and cylindrical powers and maximum and minimum edge thicknesses of aspherical, sphero-cylindrical, and ellipsoidal surfaces were compared. The results indicated that the power of the lens constructed using the toroidal surface was more accurate than those of the other three lenses. Moreover, the minimum edge thickness of the toroidal surface was 1.2%, 4.98%, and 4.87% lower than those of the aspherical, sphero-cylindrical, and ellipsoidal surfaces, respectively. The powers and edge thicknesses of toroidal surfaces with different diopters were compared in the second group. The minimum and maximum edge thicknesses were observed to be reduced by 8.97% and 6.05%, respectively, corresponding to the conic constants obtained via ray tracing. The conclusion will be significant for clinical ophthalmology and optical design for the patients with astigmatism.

Publisher:

Oficyna Wydawnicza Politechniki Wrocławskiej

Place of publication:

Wrocław

Date:

2023

Resource Type:

artykuł

Resource Identifier:

doi:10.37190/oa230304

Source:

<sygn. PWr A3481II> ; click here to follow the link ; click here to follow the link

Language:

eng

Relation:

Optica Applicata ; Optica Applicata, Vol. 53, 2023 ; Optica Applicata, Vol. 53, 2023, nr 3 ; Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki

Rights:

Wszystkie prawa zastrzeżone (Copyright)

Access Rights:

Dla wszystkich w zakresie dozwolonego użytku

Location:

Politechnika Wrocławska

Group publication title:

Optica Applicata

Edition name Date
×

Citation

Citation style:

This page uses 'cookies'. More information