Object structure
Title:

Investigation of optical detection strategies for transabdominal fetal heart rate detection using three-layered tissue model and Monte Carlo simulation

Group publication title:

Optica Applicata

Creator:

Gan, K.B. ; Zahedi, E. ; Mohd Ali, M.A.

Contributor:

Gaj, Miron. Redakcja ; Urbańczyk, Wacław. Redakcja

Subject and Keywords:

optyka ; transabdominal ; fetal heart rate ; Monte Carlo simulation ; tissue model

Description:

Optica Applicata, Vol. 41, 2011, Nr 4, s. 885-896

Abstrakt:

In this paper, the Monte Carlo technique is used to determine the optical detection strategies in three-layered (maternal, amniotic fluid and fetal) tissue model. This model is utilized to estimate the transabdominal optical power and optimum source–detector (S–D) separation. Results based on the launching of 2 million photons with 1 mW optical power showed that the expected optical power output is in the range of 10–6–10–10 W/cm2 depending on S–D separation. Considering the limit of the signal processing methods (such as adaptive noise cancelling) and the use of silicon photodetector, an S–D separation of 4 cm has been selected as a practical compromise between signal level and percentage of optical power (70%) coming from the fetal layer. Based on these findings, transabdominal fetal heart rate detection system using NIR and adaptive filtering can be designed and developed.

Publisher:

Oficyna Wydawnicza Politechniki Wrocławskiej

Place of publication:

Wrocław

Date:

2011

Resource Type:

artykuł

Source:

<sygn. PWr A3481II> ; click here to follow the link ; click here to follow the link

Language:

eng

Relation:

Optica Applicata ; Optica Applicata, Vol. 41, 2011 ; Optica Applicata, Vol. 41, 2011, Nr 4 ; Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki

Rights:

Wszystkie prawa zastrzeżone (Copyright)

Access Rights:

Dla wszystkich w zakresie dozwolonego użytku

Location:

Politechnika Wrocławska

×

Citation

Citation style: